Biogas SCHNELL Spark-Ignition Technology

Easy, Efficient Energy Generation from Biogas.

The spark-ignited gas CHP unit from SCHNELL combines innovative technology with deep expertise in generating electricity from biogas. Its low gas consumption and high ease of use make it the perfect solution for all biogas plant owners interested in high total system efficiencies.

Interested?

We look forward to hearing from you.

Contact us

Heat and Power from Biogas and Lean Gases

Biogas plays a major role in the shift away from conventional power generation and toward renewables. To get the most out of biogas, though, you need a reliable cogeneration plant that combines high efficiency with excellent flexibility. The biogas CHP unit delivers. It is the ideal choice for any project that requires low consumption and superior efficiency – from new systems to expansion to repowering. Its efficient thermal output can even support heat applications such as drying or refrigeration in addition to electricity generation.

Cleverly Combined for Maximum Efficiency

The secret of the spark-ignited CHP unit's high performance: the careful integration of its components. Proven, high-quality Liebherr gas engines deliver high total system efficiency. When combined with SCHNELL’s intelligent CHP technology, they form a high-efficiency system that generates power from biogas and sewage gas at electrical efficiencies as high as 42 percent.

Installation Tailored to You

SCHNELL spark-ignited CHP units are easy to integrate and adapt to your unique local circumstances. They are known for reliability, robustness and efficiency – from turnkey compact modules to sound-insulated container and engine room solutions.

SCHNELL SPARK-IGNITION TECHNOLOGY

ENGINE POWER
CLASS (KW
TYPEENGINEELECTRICAL
POWER (KW)
THERMAL 
POWER (KW)
ELEKTRICAL
EFFICIENCY (%)
THERMAL
EFFICIENCY (%)
RATED THERMAL
INPUT (KW)
160L4R20.1BOLIEBHERR15515440,340385
2506R20.2BOSCANIA, PV, TC, DC1225022644,240566
2506R20.3BOSCANIA, PV, DC1325023542,540588
2656R20.3BOSCANIA, PV, DC1326524942,540624
300*8V20BOSCANIA, PV, DC1630028041,739719
3508V20BOSCANIA, PV, DC1635032142,539824
410*L12V21.1BOLIEBHERR41044239421051
500L12V21.1BOLIEBHERR50050141,341,41211
525L12V21.1BOLIEBHERR52552641,341,41271
8008V4000L32MTU8007184338,61861
100012V4000L32MTU99995742,440,72355
120012V4000L32MTU1169113842,441,32755
160016V4000L32MTU1562128043,235,43616
200020V4000L32MTU1950178043,439,64493

*limited part load capability / **stoichiometric fuel rate
CR = CommonRail / PDE = pump-injector element / TC = TurboCompound / PV = passive prechamber